Formula and meaning
Convert charging power into current per phase, or calculate power from current, voltage, phase count, and power factor.
Single phase: P = U · I · cos φ · Three phase: P = √3 · U · I · cos φ
Convert single- and three-phase AC charging power and current using voltage and power factor.
Set the inputs and run the calculation.
Convert charging power into current per phase, or calculate power from current, voltage, phase count, and power factor.
Single phase: P = U · I · cos φ · Three phase: P = √3 · U · I · cos φ
At 400 V, three phases, and cos φ = 1, 11 kW is about 15.88 A per phase and 22 kW is about 31.75 A.
The model considers a balanced AC connection with sinusoidal quantities. The calculated current is not an automatic recommendation for protective-device rating or conductor cross-section. Installation design is separate.