Typical application
Suitable for securely located hubs and bushes where force or temperature-assisted assembly is available.
A tight transition to light interference fit.
Compare limit values at the current nominal size. Optionally narrow the results to a desired range in µm.
Suitable for securely located hubs and bushes where force or temperature-assisted assembly is available.
The shaft zone is above the zero line; diameter and actual limits determine whether slight clearance or interference remains.
H7/k6 is easier to remove. H7/p6 gives a stronger press fit whose load capacity should be verified separately.
From nominal size plus hole and shaft tolerance classes, the calculator returns limit sizes and minimum/maximum clearance or interference.
ISO 286 defines hole and shaft sizes. Performance in the actual assembly also depends on temperature, form, surface texture, and assembly conditions.
Differential thermal expansion can turn clearance into interference, or the reverse.
Roundness, cylindricity, and roughness are not controlled by a size fit.
Derive minimum clearance or interference from load, lubrication, and assembly needs.
Geometrical tolerances for form, orientation, location, and run-out.
Unambiguous specification of linear sizes on drawings.
Surface texture specification for sliding, sealing, or joining functions.